2011 Infiniti EX35 Base, AWDFACTORY OEM SERVICE PROCEDURE

Diagnosis Procedure

  1. PERFORM INITIALIZATION PROCEDURE

    Initialization procedure is executed and operation is confirmed.

    Refer to "ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : SPECIAL REPAIR REQUIREMENT ".

    Is the inspection result normal? 

    YES: INSPECTION END

    NO: GO TO 2.

  2. CHECK DRIVER SIDE DOOR LOCK ASSEMBLY (DOOR KEY CYLINDER SWITCH)

    Check driver side door lock assembly (door key cylinder switch).

    Refer to "COMPONENT FUNCTION CHECK ".

    Is the inspection result normal? 

    YES: GO TO 3.

    NO: Repair or replace the malfunctioning parts.

  3. CONFIRM THE OPERATION

    Confirm the operation again.

    Is the result normal? 

    YES: Check intermittent incident. Refer to "INTERMITTENT INCIDENT ".

    NO: GO TO  1.