2008 Infiniti G35 xFACTORY OEM SERVICE PROCEDURE

Component Inspection (Cooling Fan Relay)

  1. CHECK COOLING FAN RELAY
    1. Turn ignition switch OFF.
    2. Remove cooling fan relay.
    3. Check the continuity between cooling fan relay terminals under the following conditions.
      TERMINALS CONTINUITY REFERENCE

      Terminals Conditions Continuity
      3 and 5 12V direct current supply between terminals 1 and 2 Existed
      No current supply Not existed

    Is the inspection result normal?Β 

    YES: INSPECTION END

    NO: Replace cooling fan relay.

    Fig 1: Identifying Cooling Fan Relay Terminals
    G05030026Courtesy of NISSAN MOTOR CO., U.S.A.
Factory Service Tools