Check Remote Keyless Entry Receiver
- CHECK REMOTE KEYLESS ENTRY RECEIVER OUTPUT SIGNALÂ
- Turn ignition switch OFF.
- Check remote keyless entry receiver connector M98 terminal 2 (L) and ground signal with oscilloscope.
Courtesy of NISSAN MOTOR CO., U.S.A.NISSAN MOTOR CO., U.S.A.NISSAN MOTOR CO., U.S.A.
REMOTE KEYLESS ENTRY RECEIVER OUTPUT SIGNALConnector Terminal (Wire color) Condition of keyfob Voltage (Reference value) (+) (-) M98 2 Ground No function Any button is pressed
OK or NGÂ
OK: Remote keyless entry receiver circuit is OK.
NG: GO TO 2.
- CHECK REMOTE KEYLESS ENTRY RECEIVER INPUT VOLTAGEÂ
- Disconnect remote keyless entry receiver connector.
- Check voltage between remote keyless entry receiver connector M98 terminal 4 (R) and ground.
4 (Y) - Ground : Approx. 4.5VÂ
OK or NGÂ
OK: GO TO Â 4.
NG: GO TO 3.
- CHECK REMOTE KEYLESS ENTRY RECEIVER POWER SUPPLY CIRCUITÂ
- Disconnect BCM connector.
- Check continuity between remote keyless entry receiver connector M78 terminal 4 (R) and BCM connector M1 terminal 19 (R).
4 (R) - 19 (R) : Continuity should exist.Â
- Check continuity between remote keyless entry receiver connector M78 terminal 4 (R) and ground.
4 (R) - Ground : Continuity should not exist.Â
OK or NGÂ
OK: Check harness connection.
- If it is OK, replace BCM.
- If it is NG, repair or replace malfunction part.
NG: Repair or replace the harness.
- CHECK REMOTE KEYLESS ENTRY RECEIVER GROUND CIRCUITÂ
- Check continuity between remote keyless entry receiver connector M78 terminal 1 (B) and ground.
1 (B) - Ground : Continuity should exist.Â
OK or NGÂ
OK: GO TO Â 6.
NG: GO TO 5.
- Check continuity between remote keyless entry receiver connector M78 terminal 1 (B) and ground.
- CHECK REMOTE KEYLESS ENTRY RECEIVER GROUND CIRCUITÂ
- Check continuity between remote keyless entry receiver connector M78 terminal 1 (B) and BCM connector M1 terminal 18 (B)
1 (B) - 18 (B) : Continuity should exist.Â
OK or NGÂ
OK: Check harness connection.
- If it is OK, replace BCM.
- If it is NG, repair or replace malfunction part.
NG: Repair or replace the harness.
- Check continuity between remote keyless entry receiver connector M78 terminal 1 (B) and BCM connector M1 terminal 18 (B)
- CHECK REMOTE KEYLESS ENTRY RECEIVER SIGNAL CIRCUITÂ
- Check continuity between remote keyless entry receiver connector M78 terminal 2 (Y) and BCM connector M1 terminal 20 (Y).
2 (Y) - 20 (Y) : Continuity should exist.Â
- Check continuity between remote keyless entry receiver connector M78 terminal 2 (Y) and ground.
2 (Y) - Ground : Continuity should not exist.Â
OK or NGÂ
OK: Check harness connection.
- If it is OK, replace remote keyless entry receiver.
- If it is NG, repair or replace malfunction part.
NG: Repair or replace harness.
- Check continuity between remote keyless entry receiver connector M78 terminal 2 (Y) and BCM connector M1 terminal 20 (Y).
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.