2008 Infiniti EX35 Base, AWDFACTORY OEM SERVICE PROCEDURE

How to Display SRT Status

WITH CONSULT-III 

Selecting "SRT STATUS" in "DTC CONFIRMATION" mode with CONSULT-III.

For items whose SRT codes are set, a "CMPLT" is displayed on the CONSULT-III screen; for items whose SRT codes are not set, "INCMP" is displayed.

NOTE: Though displayed on the CONSULT-III screen, "HO2S HTR" is not SRT item.

WITH GST 

Selecting Service $01 with GST (Generic Scan Tool)

NO TOOLS 

A SRT code itself can not be displayed while only SRT status can be.

  1. Turn ignition switch ON and wait 20 seconds.
  2. SRT status is indicated as shown below.
    • When all SRT codes are set, MIL lights up continuously.
    • When any SRT codes are not set, MIL will flash periodically for 10 seconds.
      Fig 1: Malfunction Indicator Lamp Blinking Pattern
      G04874803Courtesy of NISSAN MOTOR CO., U.S.A.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.