2008 Infiniti EX35 Base, AWDFACTORY OEM SERVICE PROCEDURE

Diagnosis Procedure

  1. CHECK PUSH-BUTTON IGNITION SWITCH INPUT SIGNAL 
    1. Turn ignition switch OFF.
    2. Disconnect push-button ignition switch connector.
    3. Check voltage between push-button ignition switch harness connector and ground.
      TERMINALS VOLTAGE REFERENCE

      (+) (-) Voltage (V) (Approx.)
      Push-button ignition switch
      Connector Terminal
      M50 8 Ground Battery voltage

    Is the inspection result normal? 

    YES: GO TO  2.

    NO: Check the following.

    • 10A fuse [No. 9, located in fuse block (J/B)]
    • Harness for open or short between push-button ignition switch and fuse
  2. CHECK PUSH-BUTTON IGNITION SWITCH CIRCUIT 
    1. Disconnect BCM connector and push button ignition switch connector.
    2. Check continuity between BCM harness connector and push-button ignition switch harness connector.
      TERMINALS CONTINUITY REFERENCE

      Indicator BCM Push-button ignition switch Continuity
      Connector Terminal Connector Terminal
      LOCK position M123 134 M50 5 Existed
      ACC position M119 15 6
      ON position M122 93 7
    3. Check continuity between BCM harness connector and ground.
      TERMINALS CONTINUITY REFERENCE

      Indicator BCM Ground Continuity
      Connector Terminal
      LOCK position M123 134 Not existed
      ACC position M119 15
      ON position M122 93

    Is the inspection result normal? 

    YES: GO TO  3.

    NO: Repair or replace harness or connector.

  3. CHECK PUSH-BUTTON IGNITION SWITCH 

    Refer to COMPONENT INSPECTION  .

    Is the inspection result normal? 

    YES: GO TO  4.

    NO: Replace push-button ignition switch. Refer to REMOVAL AND INSTALLATION  .

  4. CHECK INTERMITTENT INCIDENT

    Refer to INTERMITTENT INCIDENT .

    INSPECTION END

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.