Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
2004 Infiniti Q45FACTORY OEM SERVICE PROCEDURE
2. Check Harness Continuity
- Turn ignition switch OFF.
- Disconnect auto trunk control unit and auto trunk motor connector.
- Check continuity between auto trunk control unit connector B110 terminal 14 and auto trunk motor connector B109 terminal 5.
- 14 (L/R) - 5 (L/R) : Continuity should exist .
- Check continuity between auto trunk control unit connector B110 terminal 14 and ground.
- 14 (L/R) - Ground : Continuity should not exist .
OK or NG
- OK : Replace auto trunk control unit.
- NG : Repair or replace harness between auto trunk control unit and auto trunk motor.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.