Procedure A
- CHECK COOLING FAN POWER SUPPLY CIRCUITÂ
- Turn ignition switch OFF.
- Disconnect cooling fan relay-1.
- Turn ignition switch ON.
- Check voltage between cooling fan relay-1 terminals 1, 3, 6 and ground with CONSULT-II or tester.
Courtesy of NISSAN MOTOR CO., U.S.A.
Voltage: Battery voltageÂ
OK or NGÂ
- OK: GO TO Â 3 .
- NG: GO TO 2.
- DETECT MALFUNCTIONING PARTÂ
Check the following.
- Joint connector-8
- Joint connector-9
- 15A fuse
- 40A fusible links
- Harness for open or short between cooling fan relay-1 and fuse
- Harness for open or short between cooling fan relay-1 and battery
- Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK COOLING FAN MOTORS CIRCUITÂ
- Turn ignition switch OFF.
- Disconnect cooling fan motor-1 harness connector and cooling fan motor-2 harness connector.
- Check harness continuity between cooling fan relay-1 terminal 5 and cooling fan motor-1 terminal 2, cooling fan motor-1 terminal 3 and body ground. Refer to Wiring Diagram.
Continuity should exist.Â
- Also check harness for short to ground and short to power.
- Check harness continuity between cooling fan relay-1 terminal 7 and cooling fan motor-2 terminal2, cooling fan motor-2 terminal 3 and body ground. Refer to Wiring Diagram.
Continuity should exist.Â
- Also check harness for short to ground and short to power.
OK or NGÂ
- OK: GO TO 4.
- NG: Repair open circuit or short to ground or short to power in harness or connectors
- CHECK COOLING FAN OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORTÂ
- Disconnect ECM harness connector.
- Check harness continuity between ECM terminal 35 and cooling fan relay-1 terminal 2. Refer to Wiring Diagram.
Continuity should exist.Â
- Also check harness for short to ground and short to power.
OK or NGÂ
- OK: GO TO Â 6 .
- NG: GO TO 5.
- DETECT MALFUNCTIONING PARTÂ
Check the following.
- Harness connectors E8, F17
- Harness for open or short between cooling fan relay-1 and ECM
- : Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK COOLING FAN RELAY-1Â
Check continuity between cooling fan relay-1 terminals 3 and 5, 6 and 7 under the following conditions.
OK or NGÂ
- OK: GO TO 7.
- NG: Replace cooling fan relay.
- CHECK COOLING FAN MOTORS-1 AND -2Â
Supply battery voltage between the following terminals and check operation.
OK or NGÂ
- OK: GO TO 8.
- NG: Replace cooling fan motors.
- CHECK INTERMITTENT INCIDENTÂ
Perform TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENTÂ .
- : INSPECTION ENDÂ
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.