2003 Infiniti M45FACTORY OEM SERVICE PROCEDURE

ECM Relay

NOTE: ECM relay testing information for FX35, FX45 and G35 is not available from the manufacturer.
  1. For relay location, see Fig 1 - Fig 4 . Remove ECM relay. Using jumper wires, apply battery to terminals No. 1 and 2. See Fig 5.
  2. Continuity should exist between terminals No. 3 and 5, and between terminals No. 6 and 7. Remove jumper wires. Continuity should not exist. If continuity is not as specified, replace relay.
Fig 1: Locating ECM Relay (FX35 & FX45)
G00248129Courtesy of NISSAN MOTOR CO., U.S.A.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.