Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
2003 Infiniti M45FACTORY OEM SERVICE PROCEDURE
EVAP System Leak Test
CAUTION:
DO NOT use compressed air. DO NOT start engine. DO NOT apply more than.6 psi (4.12 kPa) of pressure to EVAP system.
- Connect EVAP Service Port Adapter (J41413-OBD) to EVAP service port. See Fig 1. Connect a suitable pressure pump to adapter. DO NOT use compressed air. If using CONSULT-II, go to next step. If using generic scan tool, go to step Β 3.
- Turn ignition switch to ON position. Select EVAP SYSTEM CLOSE of WORK SUPPORT mode with CONSULT-II. Press START. Observe pressure indicator on CONSULT-II. Apply pressure to EVAP system until pressure indicator reaches middle of bar graph. DO NOT exceed.6 psi (4.12 kPa) of pressure. Using Leak Detector (J41416), locate EVAP leak. See VACUUM DIAGRAMS article.
- Disconnect EVAP Canister Vent Control Valve (EVAP-CVCV) and vacuum cut valve by-pass valve harness connectors. See Fig 2. Using jumper wires, apply battery voltage to EVAP-CVCV and vacuum cut valve by-pass valve terminals. Apply.2-.4 psi (1.38-2.76 kPa) of pressure to EVAP service port. DO NOT exceed.6 psi (4.12 kPa) of pressure. Remove pressure pump from EVAP service port. Using Leak Detector (J41416), locate EVAP system leak. See VACUUM DIAGRAMS article.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.