2000 Infiniti QX4FACTORY OEM SERVICE PROCEDURE

DTC P0600: A/T Control: Procedure

  1. Turn ignition off. Disconnect ECM and TCM harness connectors. See Figure. TCM is located under left side of instrument panel. Check continuity of the following:
    • Purple/White wire between TCM harness connector terminal No. 5 and ECM harness connector terminal No. 26.
    • Pink/Black wire between TCM harness connector terminal No. 6 and ECM harness connector terminal No. 27.
    • Pink wire between TCM harness connector terminal No. 7 and ECM harness connector terminal No. 35.

    See Figure and Fig 1 . If continuity exists, go to next step. If continuity does not exist, repair open circuit.

  2. No problem is currently indicated. Problem may be intermittent. See TESTING PROCEDURE under SELF-DIAGNOSTIC SYSTEM in SELF-DIAGNOSTICS - INTRODUCTION article.
Fig 1: TCM Harness Connector Terminal Identification
G00010717Courtesy of NISSAN MOTOR CO., U.S.A.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.