2000 Infiniti QX4FACTORY OEM SERVICE PROCEDURE
Generator Test
NOTE:
Terminals "S", "L", and "B" are marked on generator rear cover.
- Ensure battery is fully charged. Ensure all fuses and fusible links in power distribution box are in good condition. Power distribution box is located in front left corner of engine compartment on G20 and I30 models. On QX4 and Q45, power distribution box is located forward of right shock tower. On all models, if fusible links are okay, go to next step. If any fusible link is blown, check for short to ground in power supply between power distribution box and generator terminal "B", and repair as necessary.
- Turn ignition switch to RUN position. Observe CHARGE light on instrument panel. If CHARGE light does not illuminate, go to next step. If CHARGE light illuminates, go to step Β 4 .
- Disconnect terminals "S" and "L" at generator. Using a fused jumper wire, ground terminal "L" at harness. If CHARGE light does not illuminate, check the following and repair as necessary: CHARGE light bulb, blown warning light fuse and/or damaged wiring. If light illuminates, replace IC regulator.
- Start engine and raise engine speed to 1500 RPM. If CHARGE light does not illuminate, system is okay at this time. If light illuminates, go to next step.
- Turn engine off. Check drive belt tension, connections at terminals "B", "S" and "L" at generator, and fuse for terminal "S". If problem does not exist, go to next step. If problem exists, repair as necessary.
- Start engine and allow it to idle. If CHARGE light is illuminated, go to next step. If CHARGE light is not illuminated, system is okay at this time.
- Raise engine speed to 1500 RPM. Measure voltage at terminal "B" at generator. If voltage is greater than 15.5 volts, replace IC regulator. If voltage is less than battery voltage, field circuit is open. Repair or replace generator as necessary.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.
Rather have a pro handle this?
A certified mobile mechanic comes to your home or office. They bring the tools, you stay comfortable. No tow truck, no waiting room, no surprises.
Comes to youSame-day available12-month warranty
Get a Free QuoteNo obligation. See pricing before you book.