1992 Infiniti Q45 BaseFACTORY OEM SERVICE PROCEDURE

Bleeding TCS System

  1. Loosen TCS actuator bleeder. Remove cap and fill reservoir tank to MAX with new DOT 3 brake fluid. Do not reinstall cap at this time.
  2. Start engine, activating TCS pump. Tighten bleeder to slightly less than 9 ft. lbs. (12 N.m). Approximately 3-5 seconds after bleeder is tightened, TCS pump should stop. Turn engine off. See Fig 1 .
  3. Start engine again and loosen bleeder. Watch oil in reservoir tank. Repeat bleeding procedure until oil returning to reservoir tank does not contain air bubbles. Tighten bleeder to 9-12 ft. lbs. (12-16 N.m).
Fig 1: TCS Actuator Bleeder & Reservoir Tank
G92I00875Courtesy of NISSAN MOTOR CO., U.S.A.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.