Inspection Procedures: Notes

Check The Power Supply Circuit For The Diagnosis 

  1. Measure the voltage between terminal 16 of the data link connector and body ground.

    Specification:  approximately B+

    Fig 1: Measuring Voltage Between Terminal 16 Of Data Link Connector And Body Ground
    G12091162
  2. Is voltage within specification?

    YES 

    • Check the ground circuit for the diagnosis.

    NO 

    • Repair an open in the wire. Check and replace fuse from the engine compartment junction block.