2012 Hyundai Genesis 3.8FACTORY OEM SERVICE PROCEDURE

[CVVT Oil Control Valve (Intake)]

  1. Turn the ignition switch OFF and disconnect the battery negative (-) cable.
  2. Remove the intake manifold (Refer to "INTAKE AND EXHAUST SYSTEM " in EM group).
  3. Disconnect the CVVT oil control valve connector (A).
  4. Remove the installation bolt (B), and then remove the valve from the engine.

    [Bank 1]Β 

    Fig 1: Identifying Intake CVVT Oil Control Valve Connector And Mounting Bolt (Bank 1)
    G08834214Courtesy of HYUNDAI MOTOR AMERICA

    [Bank 2]Β 

    Fig 2: Identifying Intake CVVT Oil Control Valve Connector And Mounting Bolt (Bank 2)
    G08834215Courtesy of HYUNDAI MOTOR AMERICA