Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
2012 Hyundai Equus SignatureFACTORY OEM SERVICE PROCEDURE
Decayed Foot Lamp Control
The Decayed Foot Lamp controls the state of the Foot Lamp by IPM.
IPM receive door Lock/Unlock state from each door module by CAN
- Transitions from Foot lamp OFF state
State Description Initial condition Foot lamp OFF & IGN1 IPM=OFF & ALL DOORS CLOSED Event Transition of ALL DOORS CLOSED to ANY DOOR OPEN for more than 0.1sec. Action State changed to FOOT LAMP ON for 20 min
Turn FOOT LAMP for a duration of 20 +/-1minutesState Description Initial condition Foot lamp OFF & IGN1 IPM=OFF & ALL DOOR CLOSED Event UNLOCK by RKE CMD If SMK variant: Unlock by SMK RKE or SMK Passive Action State changed to FOOT LAMP ON for 30s
FOOT LAMP is turned ON for 30sec +/- 1 sec.State Description Initial condition Foot lamp OFF & IGN1 IPM=OFF & ALL DOOR CLOSED Event IGN1 IPM=ON and (ANY DOOR OPEN or P Position=P) Action State changed to FOOT LAMP ON
The Foot lamp is turned ON without time limitation - Transitions from Foot lamp ON for 30s state
State Description Initial condition FOOT LAMP ON for 30s & IGN1 IPM=OFF Event At least 1 door is opened more than 0.1sec (ALL DOOR NOT CLOSED = ON) Action State changed to FOOT LAMP ON for 20min
FOOT LAMP is kept ON for 20 +/-1minutesState Description Initial condition FOOT LAMP ON for 30sec & IGN1 IPM=OFF Event UNLOCK by RKE CMD If SMK variant: UNLOCK by SMK RKE or SMK Passive Action State remains FOOT LAMP ON for 30sec.
FOOT LAMP ON 30sec +/- 1 sec timer is re-initialized for an other 30sec +/- 1 sec durationState Description Initial condition FOOT LAMPON for 30sec & IGN1 IPM=OFF Event IGN1 IPM=ON & P Position=Off
ALL DOOR LOCKED
30sec timer elapsed
ATWS armedAction State changed to FOOT LAMP DECAYING
FOOT LAMP is slowly decayed during 2+/-0.2sec then off. - Transitions from Foot lamp Decaying state
State Description Initial condition FOOT LAMP DECAYING & IGN1 IPM=OFF Event Transition of ALL DOORS CLOSED to ANY DOOR OPEN for more than 0.1sec. Action State changed to FOOT LAMP ON for 20min
FOOT LAMP is kept ON for 20 +/-1minutesState Description Initial condition FOOT LAMP DECAYING & IGN1 IPM=OFF & ALL DOOR CLOSED Event UNLOCK by RKE CMD If SMK variant: UNLOCK by SMK RKE or SMK Passive Action State changed to FOOT LAMP ON for 30 sec.
FOOT LAMP is turned ON for 30sec +/- 1 sec.State Description Initial condition FOOT LAMP DECAYING Event Foot lamp decaying completed Action State changed to FOOT LAMPOFF
Turn OFF the room lampState Description Initial condition FOOT LAMP DECAYING Event IGN1 IPM=ON and (ANY DOOR OPEN or P Position=P) Action State changed to FOOT LAMP ON
The Foot lamp remains ON without time limitation
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.