2004 Hyundai Tiburon Base, StandardFACTORY OEM SERVICE PROCEDURE

Inspection Procedures

  1. CHECK OTS AND ECM CONNECTORS
    1. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.

      Are all connectors good? 

    Yes: Go to next

    No: Repair or replace it.

  2. CHECK OTS RESISTANCE
    1. Turn ignition switch to OFF and disconnect OTS connector.
    2. Check resistance of OTS between terminals 1 and 2 of the OTS connector.
    Fig 1: Checking Resistance Of OTS Between Terminals 1 & 2 Of OTS Connector
    G00883961Courtesy of HYUNDAI MOTOR CO.

    Is resistance within specification? 

    Yes: Go to next

    No: Replace OTS.

  3. CHECK POWER TO OTS
    1. Turn ignition switch to ON position.
    2. Measure voltage between terminal 1 of the OTS harness connector and chassis ground.
      Fig 2: Measuring Voltage Between Terminal 1 Of OTS Harness Connector & Chassis Ground
      G00883962Courtesy of HYUNDAI MOTOR CO.
    • Specification: approximately 5V 

    Is voltage within specification? 

    Yes: Go to next

    No: Repair open or short to chassis ground in harness.

  4. CHECK FOR SHORT TO GROUND IN HARNESS
    1. Turn ignition switch to OFF position.
    2. Disconnect ECM connector.
    3. Check for short in harness between terminals 1 and 2 of the OTS harness connector.
    4. Check for short to ground in harness between terminal 2 of the OTS harness connector and chassis ground.
    Fig 3: Checking For Short To Ground In Harness Between Terminal 2 Of OTS Harness Connector & Chassis Ground
    G00883963Courtesy of HYUNDAI MOTOR CO.
    • Specification: infinite 

    Does resistance indicate open? 

    Yes: Proceed with ECM PROBLEM PROCEDURE  .

    No: Repair short or short to chassis ground in harness.

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.