1995 Hyundai Scoupe LS, StandardFACTORY OEM SERVICE PROCEDURE

Ignition Coil Resistance

  1. Using an ohmmeter, measure primary coil resistance for cylinders No. 1 and 2 between coil connector terminals No. 1 and 3. Measure resistance for cylinders No. 3 and 4 between connector terminals No. 2 and 3. See Fig 1 . See DIS IGNITION COIL RESISTANCE tab le.
  2. To measure secondary coil resistance, disconnect ignition coil connector. Measure resistance between coil towers No. 1 and 4 and between coil towers No. 2 and 3. See DIS IGNITION COIL RESISTANCE table. Replace coil if readings are not within specification.
DIS IGNITION COIL RESISTANCE - Ohms @ 68Β°F (20Β°C)

Application Primary Secondary
Accent & Scoupe .45-.55 10,300-13,900
Fig 1: Testing DIS Coil Resistance (Accent & Scoupe)
G95B30958Courtesy of HYUNDAI MOTOR CO.