2009 Hummer H3 L5-3.7LFACTORY OEM SERVICE PROCEDURE

Variable Valve Timing Solenoid: Service and Repair




Camshaft Position Actuator Solenoid Valve Replacement

Removal Procedure

Factory service manual diagram



1. Disconnect the engine wiring harness electrical connector (1) from the camshaft position (CMP) actuator solenoid valve (6).

Factory service manual diagram



2. Remove the CMP actuator solenoid valve bolt (3).
3. Remove the CMP actuator solenoid valve (2) from the cylinder head.
Discard the O-ring seal.
4. Clean debris from the hole (1).

Installation Procedure

Factory service manual diagram



1. Install a new O-ring seal to the actuator solenoid valve (2).
2. Lightly lubricate the O-ring seal with clean engine oil.
3. Install the CMP actuator solenoid valve (2) into the cylinder head.

Caution: Refer to Fastener Caution (Fastener Caution).

4. Install the camshaft position actuator solenoid valve bolt (3).

Tighten the bolt to 10 Nm (89 lb in).

Factory service manual diagram



5. Connect the engine wiring harness electrical connector (1) to the CMP actuator solenoid valve (6).

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.