2021 Honda Pilot EX-L, FWDFACTORY OEM SERVICE PROCEDURE

DTC P2197

DTC P2197:  Front Air/Fuel Ratio (A/F) Sensor (Bank 2, Sensor 1) Signal Stuck Lean

General Description 

GHH306910Courtesy of HONDA, U.S.A., INC.

When the front air/fuel ratio (A/F) sensor (bank 2, sensor 1) is properly connected to the engine wire harness, but it is not installed in the exhaust pipe, the feedback is not done properly even if the front A/F sensor (bank 2, sensor 1) is active after starting the engine. Thus, the exhaust emissions increase. When the front A/F sensor (bank 2, sensor 1) output stays out of the normal range after the front A/F sensor (bank 2, sensor 1) becomes active, the powertrain control module (PCM) detects that the front A/F sensor (bank 2, sensor 1) is not properly installed and stores a DTC.

Monitor Execution, Sequence, Duration, DTC Type 

Execution Once per driving cycle
Sequence None
Duration 7.0 seconds or more
DTC Type Two drive cycles, MIL on

Enable Conditions 

Condition  
Fuel feedback Other than during fuel cut-off operation

Malfunction Threshold 

The front A/F sensor (bank 2, sensor 1) output voltage is 3.37* 1 (3.28)* 2 V or more for at least 7.0 seconds.

*1: '16-21, 6-Speed A/T, '16-18 9-Speed A/T

*2: '19-21 9-Speed A/T

Possible Cause 

NOTE:  The causes shown may not be a complete list of all potential problems, and it is possible that there may be other causes.

  • Front A/F sensor (bank 2, sensor 1) heater failure
  • Front A/F sensor (bank 2, sensor 1) element failure
  • Out of fuel

Confirmation Procedure 

Operating Condition 

Start the engine, and let it idle for at least 2 minutes.

With the HDS 

None.

Diagnosis Details 

Conditions for setting the DTC 

When a malfunction is detected during the first drive cycle, a Pending DTC is stored in the PCM memory. If the malfunction returns in the next (second) drive cycle, the MIL comes on and a Confirmed DTC and the freeze data are stored.

Conditions for clearing the DTC 

The MIL is cleared if the malfunction does not return in three consecutive trips in which the diagnostic runs. The MIL, the Pending DTC, the Confirmed DTC, and the freeze data can be cleared with the scan tool Clear command or by disconnecting the 12 volt battery.

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.