2021 Honda Pilot EX, AWDFACTORY OEM SERVICE PROCEDURE

DTC P2656

DTC P2656:  Rocker Arm Oil Pressure Switch A (Bank 2) Circuit Low Voltage

General Description 

GHH306962Courtesy of HONDA, U.S.A., INC.
Mode PCM sends command to the rocker arm oil control solenoid Rocker arm oil pressure switch (detected oil pressure)
Solenoid A (Bank 1) Solenoid B (Bank 1) Solenoid A (Bank 2) Switch A (Bank 1) Switch B (Bank 1) Switch A (Bank 2)
6 Cylinder Mode (Low VTEC Range) OFF OFF OFF ON (low) OFF (low) ON (low)
Mode PCM sends command to the rocker arm oil control solenoid Rocker arm oil pressure switch (detected oil pressure)
Solenoid A (Bank 1) Solenoid B (Bank 1) Solenoid A (Bank 2) Switch A (Bank 1) Switch B (Bank 1) Switch A (Bank 2)
6 Cylinder Mode (High VTEC Range) ON OFF ON OFF (high) OFF (low) OFF (high)
3 Cylinder Mode (3 Cylinders are paused) OFF ON OFF ON (low) ON (high) ON (low)

The VTEC system activates the rocker arm oil control solenoid A (bank 2) with a command from the powertrain control module (PCM), and it charges/discharges the hydraulic circuit of the VTEC mechanism that switches valve timing between Low and High. The PCM monitors oil pressure in the hydraulic circuit of the VTEC mechanism using the rocker arm oil pressure switch A (bank 2) downstream of the rocker arm oil control solenoid A (bank 2). If there is a difference between the oil pressure condition in the hydraulic circuit determined by the PCM command and the oil pressure condition determined by the status of the rocker arm oil pressure switch A (bank 2), the system is considered faulty, and a DTC is stored.

Monitor Execution, Sequence, Duration, DTC Type, OBD Status 

Execution Once per driving cycle
Sequence None
Duration 3.0 seconds or more
DTC Type One drive cycle, MIL on

Enable Conditions 

Condition Minimum Maximum
Engine Coolant temperature [ECT SENSOR 1] 50 °F (10 °C) -
Engine speed [ENGINE SPEED]* 5, 350 rpm -
Vehicle speed [VEHICLE SPEED] 6.2 mph (10 km/h) -
12 volt battery voltage [BATTERY] 10.5 V -
Shift position Other than P or N

*: Variable that is depending on the engine load.

[ ]: HDS Parameter

Malfunction Threshold 

When the rocker arm oil control solenoid A (bank 2) is ON, the rocker arm oil pressure switch A (bank 2) remains ON.

Logic Decision Rocker Arm Oil Pressure Switch A (Bank 2)
ON OFF
Rocker Arm Oil Control Solenoid A (Bank 2) Command ON Failure (P2656) Normal
OFF Normal Failure (P2657)

Possible Cause 

NOTE:  The causes shown may not be a complete list of all potential problems, and it is possible that there may be other causes.

  • Rocker arm oil control solenoid A (bank 2) failure
  • Rocker arm oil control solenoid A (bank 2) VTSB2 line open
  • Rocker arm oil control solenoid A (bank 2) VTSB2 line short
  • Rocker arm oil pressure switch A (bank 2) failure
  • Rocker arm oil pressure switch A (bank 2) VTMB2 line open
  • Rocker arm oil pressure switch A (bank 2) VTMB2 line short
  • Oil passage clogged

Confirmation Procedure 

Operating Condition 

  • 1.

    Start the engine. Hold the engine speed [ENGINE SPEED] at 3, 000 rpm without load (in P or N) until the radiator fan comes on.

  • 2.

    Drive the vehicle at an engine speed [ENGINE SPEED] 5, 350 rpm or more for at least 3 seconds

  • Drive the vehicle in this manner only if the traffic regulations and ambient conditions allow.

With the HDS 

Select the VTEC+VCM TEST in the INSPECTION MENU with the HDS, then select the VEB VTEC TEST with the HDS.

Diagnosis Details 

Conditions for setting the DTC 

When a malfunction is detected, the MIL comes on and a Pending DTC, a Confirmed DTC, and the freeze data are stored in the PCM memory.

Conditions for clearing the DTC 

The MIL is cleared if the malfunction does not return in three consecutive trips in which the diagnostic runs. The MIL, the Pending DTC, the Confirmed DTC, and the freeze data can be cleared with the scan tool Clear command or by disconnecting the 12 volt battery.

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.