2021 Honda Pilot EX, AWDFACTORY OEM SERVICE PROCEDURE

DTC P1684

DTC P1684:  Throttle Valve Return Spring Performance Problem

General Description 

GHH306861Courtesy of HONDA, U.S.A., INC.

The electronic throttle control system controls the throttle valve opening. The system includes the throttle actuator, the throttle valve, throttle position (TP) sensors A and B, the electronic throttle control system (ETCS) control relay circuit, the accelerator pedal position (APP) sensor, and the powertrain control module (PCM). The throttle valve return spring is attached to the throttle valve gear to return the throttle valve to the default position. To confirm that the throttle valve is operating normally, and if the detecting condition meets, the throttle valve moves to a specified position and closes to the target position by the throttle valve return spring. If the throttle valve does not move to the target position range, the PCM detects a throttle valve return spring malfunction and stores a DTC.

Monitor Execution, Sequence, Duration, DTC Type, OBD Status 

Execution Once per driving cycle
Sequence None
Duration 2.5 seconds or more
DTC Type One drive cycle, MIL on

Enable Conditions 

Condition Minimum Maximum
Engine coolant temperature
[ECT SENSOR 1]
158 °F (70 °C) -
12 volt battery voltage
[BATTERY]
6.0 V -
Vehicle OFF (LOCK) mode

[ ]: HDS Parameter

Malfunction Threshold 

The throttle valve opening angle is 17 ° or more, or 11 ° or less, for at least 2.5 seconds.

Possible Cause 

NOTE:  The causes shown may not be a complete list of all potential problems, and it is possible that there may be other causes.

  • Throttle valve return spring failure
  • Throttle valve friction increase (poor action)

Confirmation Procedure 

Operating Condition 

  • 1.

    Start the engine. Hold the engine speed [ENGINE SPEED] at 3, 000 rpm without load (in P or N) until the radiator fan comes on.

  • 2.

    Turn the vehicle to the OFF (LOCK) mode, and wait 10 seconds.

  • 3.

    Turn the vehicle to the ON mode.

With the HDS 

None.

Diagnosis Details 

Conditions for setting the DTC 

When a malfunction is detected, the MIL comes on and a Pending DTC, a Confirmed DTC, and the freeze data are stored in the PCM memory.

Conditions for clearing the DTC 

The MIL is cleared if the malfunction does not return in three consecutive trips in which the diagnostic runs. The MIL, the Pending DTC, the Confirmed DTC, and the freeze data can be cleared with the scan tool Clear command or by disconnecting the 12 volt battery.

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.