2012 Honda Insight EXFACTORY OEM SERVICE PROCEDURE

Recirculation Control Motor Test

  1. Open the glove box. While holding the glove box, release the glove box stops on each side from the dashboard by pushing them in, then lower the glove box (see step 1 on GLOVE BOX STRIKER REPLACEMENT ).
  2. Disconnect the 7P connector from the recirculation control motor.
    NOTE: Incorrectly applying power and ground to the recirculation control motor will damage it. Follow the instructions carefully.
  3. Connect battery power to recirculation control motor terminal No. 1, and ground terminals No. 5 and No. 7; the recirculation control motor should run smoothly. To avoid damaging the recirculation control motor, do not reverse power and ground. Disconnect terminals No. 5 or No. 7 from ground; the recirculation control motor should stop at Fresh (when terminal No. 5 is disconnected) or Recirculate (when terminal No. 7 is disconnected). Do not cycle the recirculation control motor for a long time.
    Fig 1: Identifying Recirculation Control Motor Connector Terminal
    G08094384Courtesy of AMERICAN HONDA MOTOR CO., INC.
  4. If the recirculation control motor did not run in step Β 3, remove it (see RECIRCULATION CONTROL MOTOR REPLACEMENTΒ ), then check the recirculation control linkage and door for smooth movement.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.