2012 Honda Civic L4-1.8LFACTORY OEM SERVICE PROCEDURE
Power Window Control Module: Testing and Inspection
Resetting the Power Window Control Unit
Procedure
1. Power Window Control Unit - Reset
Resetting the power window is required when any of the following have occurred:
* Power window regulator replacement or repair
* Power window motor replacement or repair
* Glass run channel replacement
* Driver's door glass replacement
* Power window master switch replacement
1. Turn the ignition switch to ON (II).
2. Move the driver's window all the way down with the driver's window DOWN switch.
3. Open the driver's door.
NOTE: Steps 4-7 must be done within 5 seconds of each other.
4. Turn the ignition switch to LOCK (0).
5. Push and hold the driver's window DOWN switch.
6. Turn the ignition switch to ON (II).
7. Release the driver's window DOWN switch.
8. Repeat step 4-7 three more times.
9. Wait at least 1 second.
10. Confirm that AUTO UP and AUTO DOWN do not work. If AUTO UP and DOWN work, go back to step 1.
11. Move the driver's window all the way down with the driver's window DOWN switch.
12. Pull up and hold the driver's window UP switch until the window reaches the fully closed position, then continue to hold the switch for at least 1 second.
13. Confirm that the power window control unit is reset by using the driver's window AUTO UP and AUTO DOWN functions:
* If the window still does not work in AUTO, repeat the procedure several times, paying close attention to the 5 second time limit between steps.
* If the window still does not work, refer to the master switch input test.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.