2007 Honda Element SC, AutomaticFACTORY OEM SERVICE PROCEDURE

Symptom Troubleshooting Index

SYMPTOM TROUBLESHOOTING TABLE

Symptom Diagnostic procedure
Charging system indicator does not come on with the ignition switch ON (II) Troubleshoot the charging system indicator circuit (see CHARGING SYSTEM INDICATOR CIRCUIT TROUBLESHOOTING  ).
Charging system indicator stays on
  1. Check for PGM-FI DTCs (see GENERAL TROUBLESHOOTING INFORMATION ).
  2. Troubleshoot the charging system indicator circuit (see CHARGING SYSTEM INDICATOR CIRCUIT TROUBLESHOOTING  ).
  3. Check for a broken drive belt (see DRIVE BELT INSPECTION  ).
  4. Check the drive belt auto-tensioner (see DRIVE BELT AUTO-TENSIONER INSPECTION  ).
Battery discharged
  1. Check for excessive parasitic electrical current draw with the ignition switch is OFF, and the key removed. The multiplex control unit may take up to 10 minutes to turn off (sleep mode) for some models.
  2. Check for a broken drive belt (see DRIVE BELT INSPECTION  ).
  3. Check the drive belt auto-tensioner (see DRIVE BELT AUTO-TENSIONER INSPECTION  ).
  4. Troubleshoot the alternator and regulator circuit (see ALTERNATOR AND REGULATOR CIRCUIT TROUBLESHOOTING  ).
  5. Check for a poor connection at the battery terminal.
  6. Test the battery (see BATTERY TEST ).
Battery overcharged
  1. Troubleshoot the alternator and regulator circuit (see ALTERNATOR AND REGULATOR CIRCUIT TROUBLESHOOTING  ).
  2. Test the battery (see BATTERY TEST ).
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.