2002 Honda Civic SiFACTORY OEM SERVICE PROCEDURE
Brake Pedal Position Switch Signal Circuit Troubleshooting
- Check the brake lights.
- Are the brake lights on without pressing the brake pedal?
- YES: Inspect the brake pedal position switch adjustment (see DISC & DRUM - EXCEPT HYBRID ).
- NO: Go to step 2.
- Are the brake lights on without pressing the brake pedal?
- Press the brake pedal.
- Do the brake lights come on?
- YES: Go to step 3.
- NO: Go to step 4.
- Do the brake lights come on?
- Measure voltage between ECM connector terminals A24 and E22 with the brake pedal pressed.
- Is there battery voltage?
- YES: The brake pedal position switch signal is OK.
- NO: Repair open in the wire between the ECM (E22) and the brake pedal position switch.
- Is there battery voltage?
- Inspect the No. 7 HORN, STOP (15A) fuse in the under-hood fuse/relay box.
- Is the fuse OK?
- YES: Repair open in the wire between the brake pedal position switch and the No. 7 HORN, STOP (15A) fuse. If the wire is OK, replace and adjust the brake pedal position switch (see DISC & DRUM - EXCEPT HYBRID ).
- NO: Repair short in the wire between the ECM (E22) and the No. 7 HORN, STOP (15A) fuse. Replace the No. 7 HORN, STOP (15A) fuse.
- Is the fuse OK?
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.