2000 Honda Prelude Base, AutomaticFACTORY OEM SERVICE PROCEDURE

Generators & Regulators: Description

NOTE: For Passport information, refer to Rodeo in ISUZU section.

CR-V and Prelude are equipped with Denso generators. Civic 2-door models are equipped with either Denso or Mitsubishi generators. Civic 3-door and 4-door models are equipped with Mitsubishi generators.

The Denso and Delphi generators use 4 positive and 4 negative diodes to rectify current. The Mitsubishi generator uses 6 diodes to rectify current and 3 diodes to supply current to voltage regulator. A voltage regulator, which is part of the generator, controls charging system voltage based on commands from Engine Control Module (ECM) or Powertrain Control Module (PCM).

Charging system incorporates Electric Load Detector (ELD), which measures load on the charging system. ELD sends signal to the ECM/PCM, which controls the voltage regulator. By adjusting voltage output, ECM/PCM reduces mechanical load on engine for better fuel economy.

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.