2000 Honda Insight L3-1.0L HybridFACTORY OEM SERVICE PROCEDURE

Ignition Timing: Testing and Inspection

Ignition Timing Inspection

1. Connect the Honda PGM tester to the data link connector (DLC), and check for DTC's. If a DTC is present, diagnose and repair the cause before inspecting the ignition timing.
2. Start the engine. Hold the engine at 3,000 rpm with no load (in Neutral) until the radiator fan comes on, then let it idle.
3. Check the idle speed, and adjust it if necessary.
4. Follow the tester's prompts to get the tester in the "SCS" mode (see the tester operator's manual).

Factory service manual diagram



5. Connect the timing light to the No. 1 ignition coil wires.

Factory service manual diagram



6. Aim the light toward the pointer (A) on the oil pump. Check the ignition timing under a no load conditions; headlights, blower fan, rear window defogger, and air conditioning are not operating. If the ignition timing differs from the specification below, replace the engine control module (ECM).

Ignition Timing:
12 ° ± 2 ° BTDC (RED mark (B)) during idling in neutral

7. Turn the ignition switch OFF.
8. Disconnect the PGM Tester and timing light.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.