1992 Honda Civic SiFACTORY OEM SERVICE PROCEDURE

Engine Controls - Sensor Operating Range Charts: Introduction

Sensor operating range information can help determine if a sensor is out of calibration. Although an out-of-calibration sensor may not set a trouble code, it may cause driveability problems.

NOTE: Unless stated otherwise in test procedure, perform all voltage tests using a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance.
COOLANT TEMPERATURE (TW) SENSOR RESISTANCE TEST (1)

Temperature - °F (°C) Ohms
-4 (-20) 15,000-18,000
68 (20) 1000-4000
176 (80) 200-400
(1) Measure resistance across sensor terminals.
INTAKE AIR TEMPERATURE (TA) SENSOR RESISTANCE TEST (1)

Temperature - °F (°C) Ohms
-4 (-20) 15,000-18,000
68 (20) 1000-4000
176 (80) 200-400
(1) Measure resistance across sensor terminals.
MAP SENSOR VOLTAGE TEST (1)

Vacuum Applied - In. Hg. Volts
0 2.8-3.0
5 2.3-2.5
10 1.8-2.0
15 1.3-1.5
20 .8-1.0
25 .3-.5
(1) Measure voltage at appropriate ECU terminals. See WIRING DIAGRAMS article in the ENGINE PERFORMANCE Section.
EGR LIFT SENSOR VOLTAGE TEST (1)

Position Volts (Approximate)
Accord & Prelude
Fully Closed 1.2
Fully Open 4.0
Civic
Fully Closed 1.0
Fully Open N/A
(1) Measure voltage at appropriate ECU terminals. See WIRING DIAGRAMS article in the ENGINE PERFORMANCE Section. Voltage should increase smoothly as vacuum is applied.
OXYGEN SENSOR VOLTAGE TEST (1)

Condition Volts
Lean Less Than 0.4
Rich Greater Than 0.6
(1) Measure voltage between ground and O2 sensor terminal using a high-impedance DVOM.
THROTTLE ANGLE (POSITION) SENSOR SPECIFICATIONS

Condition (1) Volts
Throttle Valve
Fully Closed .5
Wide Open 4.5
(1) Voltage change from fully closed to wide open should be smooth.
VEHICLE SPEED SENSOR VOLTAGE TEST

Application Volts
All Models (1) (2) 0-5
(1) Backprobe terminals at sensor.
(2) Pulses between 0 and 5 volts with sensor turning.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.