Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
1987 Honda Civic Base, 2D HatchbackFACTORY OEM SERVICE PROCEDURE
Manifold Air Pressure Sensor (Map Sensor)
- On CRX Si, disconnect vacuum hose No. 21 (hose between throttle body and MAP sensor) at throttle body. Plug fitting in throttle body. Connect vacuum pump to open end of vacuum hose. On all models, unplug wiring harness connector from control unit. Connect System Checker Harness (07999-PD60000A ).
- On CRX Si, apply vacuum to MAP sensor. On all models, turn ignition on. Connect digital voltmeter positive probe to C15 terminal on Prelude, C11 terminal on all other models, of system checker harness and negative probe to C14 terminal. Measure voltage between terminals.
- On Prelude, if reading is not 4.75-5.25 volts, replace ECU. If voltage was 4.75-5.25 volts, connect positive rest lead to C11 terminal and negative lead to C14 terminal. If reading is not 2.76-2.96 volts, repair open or short in wire between MAP sensor and C11, C14 or C15 terminals on ECU. If wire are okay, replace MAP sensor.
- On all other models, voltage should be as indicated in MAP SENSOR VOLTAGE (ALL EXCEPT PRELUDE)Β table. If not, replace MAP sensor.
MAP SENSOR VOLTAGE (ALL EXCEPT PRELUDE)
| Voltage | Vacuum In. Hg |
|---|---|
| .5 | 26 |
| 1.41 | 16 |
| 4.5 | 0 |
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.