1985 Honda Civic DX, AutomaticFACTORY OEM SERVICE PROCEDURE

Idle Control Solenoid Valve

  1. Idle control solenoid valve is activated by commands from ECU. When solenoid valve opens, vacuum enters hose between air flow tube and solenoid valve. Idle speed increases for a short period after starting engine and whenever electrical loads are turned on.
    NOTE: Vacuum will disappear when engine RPM is raised over 1700 RPM.
  2. While solenoid valve is being activated, 9 volts or more should be available between Black terminal (A) and Light Green (B) of valve leads.
  3. Connect the positive battery terminal to the Black/Yellow terminal of control box and negative battery terminal to Green/Black terminal. Disconnect vacuum hose No. 28 from intake manifold. Apply vacuum to vacuum hose No. 26. It SHOULD NOT hold vacuum.
  4. On Civic CRX Si models, open control box lid and disconnect wiring harness from control box. Disconnect vacuum hose form between idle control solenoid valve and No. 10 vacuum hose. Connect vacuum gauge to hose and apply vacuum. It should hold vacuum.
  5. Connect battery positive terminal to control box connector Black terminal and negative terminal to Light Green terminal. Apply vacuum to hose. It SHOULD NOT hold vacuum.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.