1994 Geo Tracker Base, 1.6 U, AutomaticFACTORY OEM SERVICE PROCEDURE

Pressure Limit Valve

  1. Disconnect pressure limit valve connector. Check resistance of isolation valve solenoid winding between ISO and GND terminals. See Fig 1 . If resistance is not 3-6 ohms at approximately 68°F (20°C), replace pressure limit valve.
  2. Check resistance of dump valve solenoid winding between pressure limit valve DUMP and GND terminals. If resistance is not1-3 ohms at approximately 68°F (20°C), replace pressure limit valve.
  3. Check resistance of reset switch across RESET terminal and pressure limit valve body. Resistance reading should be infinite. If any resistance value is not within specification, replace pressure limit valve as an assembly.
Fig 1: Testing Pressure Limiting Valve
G93I83772Courtesy of GENERAL MOTORS CORP.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.