1994 Geo Metro XFiFACTORY OEM SERVICE PROCEDURE

Reading Trouble Codes

  1. Perform on-board diagnostic system check before diagnosing vehicle using self-diagnostic system. See appropriate ON-BOARD DIAGNOSTIC (OBD) SYSTEM CHECK chart under DIAGNOSTIC CODE CHARTS.
  2. Fault codes can be retrieved using a scan tester connected to Data Link Connector (DLC) or by counting flashes of Malfunction Indicator Light (MIL) after grounding either DIAG SW connector in fuse block or diagnostic request terminal in duty check data link connector, located on left side of firewall. See Fig 1 .
  3. To retrieve code(s) using DIAG SW connector in fuse block, remove spare fuse from fuse block and insert into DIAG SW connector terminal. See Fig 1 . Turn ignition on and observe MIL to read fault code(s). Proceed to appropriate chart(s) under DIAGNOSTIC CODE CHARTS to diagnose fault codes. See SELF-DIAGNOSTICS DIRECTORY table.
  4. To retrieve code(s) using the duty check data link connector, connect jumper wire between duty check data link connector terminals No. 2 and 4. See Fig 1 . Turn ignition on and observe MIL to read fault code(s). If fault codes are stored, code will flash 3 times, starting with the lowest code. Proceed to appropriate chart(s) under DIAGNOSTIC CODE CHARTS to diagnose fault codes. See SELF-DIAGNOSTICS DIRECTORY table.
  5. If no fault codes are stored, MIL will flash Code 12, indicating ECM diagnostic system is operating.
Fig 1: Locating & Identifying Data Link Connectors (Metro)
G93B78361Courtesy of GENERAL MOTORS CORP.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.