1992 Geo Metro L3-61 1.0LFACTORY OEM SERVICE PROCEDURE

Ignition Timing: Adjustments

NOTE: Refer to the Vehicle Emission Control Information Label located in the engine compartment. Follow all instructions on the label.

1. With the ignition "OFF," connect the pick-up lead of the timing light to the number one spark plug. Use a jumper lead between the wire and plug, or an inductive type pick-up. DO NOT pierce the wire, or attempt to insert a wire between the boot and the wire.

2. Connect the timing light power leads according to the manufacturers instructions.

Factory service manual diagram





3. Remove cap on diagnostic connector which is located next to the ignition coil. Insert a jumper wire between the diagnostic connector terminals C and D.

Checking Ignition Timing:

Factory service manual diagram





4. START the engine and aim the timing light at the timing mark. The line on the pulley will line up at the timing mark.

Factory service manual diagram





^ If a change is necessary, loosen the distributor hold-down clamp bolt at the base of the distributor.
^ While observing the mark with the timing light, slightly rotate the distributor until the line indicates the correct timing. Tighten the hold down bolt to 14 N-m (19 lbs. ft.) and recheck the timing.

5. Turn "OFF" the engine and remove the timing light.

6. Reconnect the number one spark plug wire, if removed, and remove the jumper wire on diagnostic connector and re-install connector cap.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.