Code 21, O2 Sensor Circuit/Open Or Short Circuit
ECM supplies approximately .45 volt between ECM terminals OX+ and OX1. If voltage is measured with a 10-megohm DVOM, reading may be as low as .32 volt. The O2 sensor produces a varying voltage as engine reaches normal operating temperature. Voltage will vary from .1-.9 volt.
The O2 sensor does not produce a voltage until sensor reaches 600°F (316°C). When sensor temperature is less than 600°F (316°C), an open loop condition exists.
- Code 21 will set if the following conditions are present for 60 seconds: engine is at normal operating temperature, at least 2 minutes have passed since engine start, and O2 signal voltage is steady between 0-1 volt.
- Determines if problem is faulty O2 sensor, or faulty ECM and wiring.
- Use a 10-megohm DVOM for this test. This checks continuity of Red and Black wires. If Black wire is open, ECM voltage on Black wire will be greater than .6 volt.
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.