1990 Geo Tracker L4-1590cc 1.6LFACTORY OEM SERVICE PROCEDURE

Leak Testing

Following overhaul of the compressor, conduct this leak test to make sure that unit reassembly was sound.

1. Disconnect lines from service valve fittings on compressor.

Important
^ Cap refrigerant line fittings to keep dirt and moisture out of the system.

2. Connect a manifold gage to compressor service valve.
3. Charge compressor with refrigerant until the pressure is 296 kPa (43 psi).
4. Check component for leaks using a gas leak detector.
5. If leakage is found, repair or replace compressor.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.