2022 Genesis GV70 2.5TFACTORY OEM SERVICE PROCEDURE

Canister Close Valve (CCV): Inspection

  1. Turn the ignition switch OFF.
  2. Disconnected canister close valve connector.
  3. Measure resistance between the canister close valve terminals 1 and 2.
    G14753252Courtesy of HYUNDAI MOTOR AMERICA
  4. Check that the resistance is within the specification.

    Specification:Β  19.5 - 22.5 [20Β°C (68Β°F)]

  5. Disconnect the vapor hose connected with the canister from the CCV.
  6. Connect a vacuum pump to the nipple.
  7. Apply vacuum to the valve with the battery power (B +) applied.

    Specification:Β  Vacuum maintained

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.