2007 GMC Sierra Classic 1500 HD, RWDFACTORY OEM SERVICE PROCEDURE

Starter/Generator Control Module SGCM Connector End View C5 (HP2)

Fig 1: Starter/Generator Control Module (SGCM) C5 Connector End View (HP2)
GM1391786Courtesy of GENERAL MOTORS CORP.
Starter/Generator Control Module (SGCM) C5 Connector Part Information (HP2)

Connector Part Information 
  • OEM: 15416860
  • Service: See Catalog
  • Description: 7-Way F GT 280/150 Series Sealed (BK)
Terminal Part Information 
  • Terminal/Tray: See Terminal Repair Kit
  • Core/Insulation Crimp: See Terminal Repair Kit
  • Release Tool/Test Probe: See Terminal Repair Kit
Starter/Generator Control Module (SGCM) C5 Connector Terminal Identification (HP2)

Pin Wire Color Circuit No. Function
A - - Not Used
B WH 5685 APO Neutral
C OG 5595 High Voltage Interlock Loop Signal - 2
D BK 50 Ground
E PU 5087 High Voltage Interlock Loop Signal - 1
F D-GN 5686 Ground
G BK 5683 APO Phase A
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.