Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
2004 GMC Jimmy 2D Utility, Part Time, AutomaticFACTORY OEM SERVICE PROCEDURE
Torque Specifications
TORQUE SPECIFICATIONS
| Application | Ft. Lbs. (N.m) | |
|---|---|---|
| Accumulator-To-Evaporator Fitting | 21 (28) | |
| Compressor | ||
| Discharge Hose-To-Condenser Fitting | 21 (28) | |
| Mounting Bolts | 37 (50) | |
| Suction/Discharge Hose-To-Compressor Bolt | 24 (33) | |
| Suction Hose-To-Accumulator Fitting | 35 (48) | |
| Evaporator | ||
| Tube-To-Condenser Fitting | 21 (28) | |
| Tube-To-Evaporator Fitting | 21 (28) | |
| Heater | ||
| Inlet & Outlet Hoses Bracket Bolt-To-Generator (4.3L) | 18 (25) | |
| Inlet & Outlet Hoses Bracket Bolt-To-Generator Mounting Bracket | 37 (50) | |
| Inlet Hose Fitting At Intake Manifold | 17 (24) | |
| Refrigerant Filter Retaining Nuts | 11 (15) | |
| INCH Lbs. (N.m)Β | ||
| Accumulator Clamp Screw/Bolt | 88 (10) | |
| Air Distributor Duct Mounting Screw/Bolt | 17 (1.9) | |
| Air Inlet Assembly Mounting Stud | 40 (4.5) | |
| Air Temperature Actuator Mounting Screws | 17 (1.9) | |
| Blower | ||
| Assembly Mounting Nut/Screw/Bolt/Stud | 40 (4.5) | |
| Motor Access Cover Screw/Bolt (Except Utility) | 22 (2.5) | |
| Motor Access Cover Screw/Bolt (Utility Only) | 17 (1.9) | |
| Motor Mounting Bolts | 40 (4.5) | |
| Motor Relay Bracket Mounting Screw/Bolt | 17 (1.9) | |
| Motor Resistor Mounting Screw/Bolt | 17 (1.9) | |
| Body Harness Connector (C203) Support Bracket Mounting Nuts | 80 (9) | |
| Compressor | ||
| Low Pressure Switch | 44 (5) | |
| Pressure Relief Valve | 80 (9) | |
| Condenser Insulator Retaining Screw/Bolt | 17 (1.9) | |
| Electric Actuator (Temperature) Retaining Screw/Bolt | 17 (1.9) | |
| Evaporator | ||
| & Blower Module Heat Shield Mounting Screw/Bolt (Utility Only) | 19 (2.2) | |
| & Blower Module Mounting Nut/Screw/Bolt | 40 (4.5) | |
| Case Section-To-Blower Case Section Retaining Screw/Bolt | 17 (1.9) | |
| Evaporator Tube Clip Screw/Bolt | 17 (1.9) | |
| Floor Air Outlet Mounting Screw/Bolt (Pickup Only) | 17 (1.9) | |
| Heater | ||
| Core Access Cover Screws | 17 (1.9) | |
| & Vent Module Mounting Nut/Screw/Bolt | 40 (4.5) | |
| HVAC Control Assembly Mounting Screw/Bolt (C42 & C60) | 17 (1.9) | |
| Intermediate Bracket Bolts | 88 (10) | |
| Knee Bolster Bracket Nut | 49 (5.5) | |
| Throttle Control Cable Bracket Nut | 106 (12) | |
| Vacuum Control Assembly Retaining Screws | 18 (2) | |
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.