1990 GMC Forward Control 3.9 LFACTORY OEM SERVICE PROCEDURE

Code 13: Open Oxygen Sensor Circuit: Notes

When exhaust temperature is less than 600°F (316°C), the O2 sensor is open and produces no voltage. An open sensor circuit or cold sensor will not allow system to enter closed loop operation.

NOTE: Test numbers refer to test numbers on diagnostic chart.

Test Number 1)  Code 13 will set at normal operating temperature if at least 2 minutes have passed since engine start, O2 signal voltage is steady between .35-.55 volt and throttle position sensor signal is above idle. All conditions must be met for at least 1 minute.

Test Number 2)  This determines if fault is in O2 sensor, ECM or wiring.

Test Number 3)  Use only a high-impedance Digital Volt-Ohmmeter (DVOM) while checking for continuity in signal and ground circuits. If ground circuit is open, voltage on signal circuit will be greater than .6 volt.

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.