1985 GMC Forward Control 6.2 J, StandardFACTORY OEM SERVICE PROCEDURE

Engine Will Not Start

NOTE: If a tachometer is connected to the tachometer terminal, disconnect it before proceeding with the test.
  1. Check spark at plug using Test Plug (J-26792), or equivalent, while cranking engine. See Fig 1. If no spark is exhibited from first wire, check a second wire. If a few sparks occur, and then nothing, it is considered no spark. If spark occurs, check fuel system and spark plugs.
    Fig 1: Modifying Spark Plug for Testing A commercial spark tester may also be used.
    G9008
  2. If no spark occurs, check voltage at ignition coil "B+" (battery) terminal while cranking engine. If reading is under 7 volts, repair primary wire circuit.
  3. If reading is 7 volts or more, check "TACH" terminal voltage with ignition on. If reading is less than 1 volt, replace ignition coil. If reading is from 1 to 10 volts, replace module and check for spark. If spark occurs, system is OKAY. If no spark occurs, replace ignition coil.
  4. If reading is more than 10 volts, check for spark at coil output terminal using Test Plug (J-26792) while cranking engine. See Fig 2. If spark occurs, check cap and rotor for damage.
    Fig 2: Checking for Spark at Ignition Coil Output Terminal Integral coil model is shown.
    G9009
  5. If no spark occurs, remove pick-up coil connector from module. Turn ignition on. With high input impedance voltmeter, observe voltage at "TACH" terminal while test lamp is momentarily connected to module "P" terminal (NOT MORE THAN 5 SECONDS). See Fig 3.
  6. If no drop in voltage occurs, check module ground circuit and for open wires from coil to distributor. If OKAY, replace module. If voltage drop does occur, check for spark from coil with Test Plug (J-26792) as test lamp is REMOVED from module "P" terminal.
  7. If spark occurs, replace pick-up coil. If no spark, use a module tester and follow instructions. If no module tester is available, check ignition coil ground circuit. If okay, replace ignition coil. Repeat check for spark from coil as in step 6).
  8. If spark occurs, system is okay. If no spark occurs, install original coil and replace module.
Fig 3: Checking Distributor Components with Voltmeter & Test Light Integral coil model is illustrated.
G9010
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.