2007 Freightliner Sprinter 2500 V6-3.0L DSL TurboFACTORY OEM SERVICE PROCEDURE
Removal
REMOVAL
The fuel level sending unit (fuel level sensor) and float assembly is located on the side of the fuel pump module (4).
1. Remove fuel pump module from fuel tank..
2. Unplug sensor's 2-wire harness from pump module electrical connector.
3. Before disconnecting wiring from 2-wire harness electrical connector, note position of each wire in the connector. Record this position.
4. Disconnect wiring from 2-wire harness electrical connector using a terminal pick / removal tool.
5. To remove sending unit from pump module, press on plastic locking tabs (1) while sliding sending unit (4) on its tracks.