2022 Ford F-150 Lightning ProFACTORY OEM SERVICE PROCEDURE

Pinpoint Test Ax: SASM (Steering Angle Sensor Module) Communication Concern With The Abs (Anti-Lock Brake System) Module

Refer to VEHICLE DYNAMIC SYSTEMS for schematic and connector information.

Normal Operation and Fault Conditions 

REFER to: Anti-Lock Brake System (ABS) and Stability Control - System Operation and Component Description .

With the ignition ON, the ABS module sends messages to the GWM over the FD-CAN, the GWM relays the messages to the SASM over the HS-CAN2. If the SASM does not receive these messages within a certain time frame, the module sets Diagnostic Trouble Codes (DTCs). This can be due to a ABS failure, a circuit failure on the CAN network or an excessive load on the network.

DTC Fault Trigger Conditions 

DTC Description Fault Trigger Condition
SASM U0121:00 Lost Communication With Anti-Lock Brake System (ABS) Control Module "A": No Sub Type Information Sets if the SASM detects any of the ABS module messages are missing.
SASM U0415:00 Invalid Data Received from Anti-Lock Brake System (ABS) Control Module "A": No Sub Type Information Sets if the SASM receives invalid data in any of the following ABS module messages: steering wheel compensation angle, vehicle speed qualifier fault, vehicle speed counter failure or the vehicle speed checksum failure messages.

Possible Sources 

  • Wiring, terminals or connectors
  • Network communication concern
  • ABS module
  • SASM

PINPOINT TESTS AX: SASM COMMUNICATION CONCERN WITH ABS MODULE

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.