2021 Ford F-150 TremorFACTORY OEM SERVICE PROCEDURE
Pinpoint Tests RG: Reductant Pump: Introduction
NOTE:
Regeneration may occur during normal operation. During regeneration, diagnostic procedures may display biased values. If a regeneration occurs during diagnostic procedures, allow the process to complete before continuing diagnostics.
This pinpoint test is intended to diagnose the following:
- reductant pump
- reductant pump control module
- harness circuits: RDPAP, RDPBP, RDPC, RDPCP, RDPGND, RDPM and VPWR
- reductant dosage control module (5H298)
- PCM (12A650)
| Vehicle | Connector | Pin | Circuit |
|---|---|---|---|
| Transit Connect | A | 4 3 |
RDPPWR RDPC |
| All other vehicles | B | 11 16 8 15 7 |
GND RDPCP RDPBP GND RDPAP |
| Pin | Circuit |
|---|---|
| 7 | RDPCP (Reductant Pump C Phase) |
| 2 | RDPBP (Reductant Pump B Phase) |
| 6 | RDPAP (Reductant Pump A Phase) |
| 3 | RDPM (Reductant Pump Monitor) |
| 4 | RDPC (Reductant Pump Control) |
| 1, 8 | GND (Ground) |
| 5 | VPWR (Vehicle Power) |
| Pin | Circuit |
|---|---|
| 51 | RDPPWR (Reductant Pump Power) |
| 29 | RDPC (Reductant Pump Control) |
| Pin | Circuit |
|---|---|
| 20 | RDPM (Reductant Pump Monitor) |
| 17 | RDPC (Reductant Pump Control) |
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.