2021 Ford Explorer STFACTORY OEM SERVICE PROCEDURE

General Specifications

Item Specification
2.3L EcoBoost - Base and XLT without trailer tow vehicles 
Rating 150 amps
Generator amps at 80.6 deg. F (27 deg. C) 94.7 amps at 750 rpm (min) to 134.7 amps at 2, 500 rpm (max)
Generator pulley ratio 2.76
Generator pulley replaceable Yes
Generator pulley type Overrunning Alternator Decoupler (OAD)
Voltage regulator type Electronic internal with generator
2.3L EcoBoost - Limited and XLT with trailer tow vehicles 
Rating 220 amps
Generator amps at 80.6 deg. F (27 deg. C) 112.1 amps at 750 rpm (min) to 177.3 amps at 2, 500 rpm (max)
Generator pulley ratio 2.44
Generator pulley replaceable Yes
Generator pulley type Overrunning Alternator Decoupler (OAD)
Voltage regulator type Electronic internal with generator
3.0L EcoBoost - All except police vehicles 
Rating 220 amps
Generator amps at 80.6 deg. F (27 deg. C) 98.1 amps at 625 rpm (min) to 180 amps at 2, 500 rpm (max)
Generator pulley ratio 2.69
Generator pulley replaceable Yes
Generator pulley type Overrunning Alternator Decoupler (OAD)
Voltage regulator type Electronic internal with generator
3.0L EcoBoost - Police vehicles 
Rating 250 amps
Generator amps at 80.6 deg. F (27 deg. C) 106.5 amps at 625 rpm (min) to 199 amps at 2, 500 rpm (max)
Generator pulley ratio 2.69
Generator pulley replaceable Yes
Generator pulley type Overrunning Alternator Decoupler (OAD)
Voltage regulator type Electronic internal with generator
3.3L Duratec - All except police vehicles 
Rating 200 amps
Generator amps at 80.6 deg. F (27 deg. C) 95.1 amps at 625 rpm (min) to 184 amps at 2, 500 rpm (max)
Generator pulley ratio 2.67
Generator pulley replaceable Yes
Generator pulley type Overrunning Alternator Decoupler (OAD)
Voltage regulator type Electronic internal with generator
3.3L Duratec - Police vehicles 
Rating 250 amps
Generator amps at 80.6 deg. F (27 deg. C) 106.5 amps at 625 rpm (min) to 199 amps at 2, 500 rpm (max)
Generator pulley ratio 2.67
Generator pulley replaceable Yes
Generator pulley type Overrunning Alternator Decoupler (OAD)
Voltage regulator type Electronic internal with generator
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.

Rather have a pro handle this?

A certified mobile mechanic comes to your home or office. They bring the tools, you stay comfortable. No tow truck, no waiting room, no surprises.

Comes to youSame-day available12-month warranty
Get a Free Quote

No obligation. See pricing before you book.