2021 Ford Escape Titanium Plug-In HybridFACTORY OEM SERVICE PROCEDURE

General Specifications Primary Generator

WARNING: This page is about a different car, the 2021 Ford F-150. However, it is still accessible from the selected car via links, so may be relevant.
Item Specification
2.7L EcoBoost, 3.3L Duratec and 3.5L EcoBoost without climate controlled seats or Alternating Current (AC) power outlet socket - 200 amp 
Generator amps at 80.6°F (27°C) 107 amps at 625 rpm (min) to 201 amps at 2, 500 rpm (max)
Generator pulley ratio 2.67:1
Generator pulley replaceable Yes
Generator pulley type Overrunning Alternator Decoupler (OAD)
Voltage regulator type Electronic internal with generator
2.7L EcoBoost, 3.3L Duratec and 3.5L EcoBoost with climate controlled seats or Alternating Current (AC) power outlet socket - 240 amp 
Generator amps at 80.6°F (27°C) 137 amps at 625 rpm (min) to 243 amps at 2, 500 rpm (max)
Generator pulley ratio 2.67:1
Generator pulley replaceable Yes
Generator pulley type Overrunning Alternator Decoupler (OAD)
Voltage regulator type Electronic internal with generator
3.0L Power Stroke Diesel - 250 amp 
Generator amps at 80.6°F (27°C) 116 amps at 625 rpm (min) to 254 amps at 2, 500 rpm (max)
Generator pulley ratio 2.66:1
Generator pulley replaceable Yes
Generator pulley type Overrunning Alternator Decoupler (OAD)
Voltage regulator type Electronic internal with generator
5.0L Ti-VCT without climate controlled seats, snowplow or Alternating Current (AC) power outlet socket - 200 amp 
Generator amps at 80.6°F (27°C) 115 amps at 625 rpm (min) to 202 amps at 2, 500 rpm (max)
Generator pulley ratio 2.81:1
Generator pulley replaceable Yes
Generator pulley type Overrunning Alternator Decoupler (OAD)
Voltage regulator type Electronic internal with generator
5.0L Ti-VCT with climate controlled seats, snowplow or Alternating Current (AC) power outlet socket - 240 amp 
Generator amps at 80.6°F (27°C) 149 amps at 625 rpm (min) to 244 amps at 2, 500 rpm (max)
Generator pulley ratio 2.81:1
Generator pulley replaceable Yes
Generator pulley type Overrunning Alternator Decoupler (OAD)
Voltage regulator type Electronic internal with generator
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.