2021 Ford Escape Titanium Plug-In HybridFACTORY OEM SERVICE PROCEDURE

Diagnostic Trouble Code (DTC) Chart

Diagnostics in this article assume a certain skill level and knowledge of Ford-specific diagnostic practices. REFER to: Diagnostic Methods .

Diagnostic Trouble Code Chart 

Module DTC Description Action
BCM B1554:11 Wireless Accessory Charger Enable\Disable: Circuit short to ground GO to Pinpoint Test A 
BCM B1554:13 Wireless Accessory Charger Enable\Disable: Circuit open GO to Pinpoint Test A 
WACM U0140:00 Lost Communication With Body Control Module: No Sub Type Information GO to Pinpoint Test D 
WACM U0184:00 Lost Communication With Radio: No Sub Type Information GO to Pinpoint Test F 
WACM U0257:00 Lost Communication With Front Controls / Display Interface Module: No Sub Type Information GO to Pinpoint Test E 
WACM U201A:51 Control Module Main Calibration Data: Not Programmed GO to Pinpoint Test H 
WACM U2100:00 Initial Configuration Not Complete: No Sub Type Information GO to Pinpoint Test H 
WACM U2101:00 Control Module Configuration Incompatible: No Sub Type Information GO to Pinpoint Test H 
WACM U3000:41 Control Module: General Checksum GO to Pinpoint Test G 
WACM U3000:42 Control Module: General Memory Failure GO to Pinpoint Test G 
WACM U3000:49 Control Module: Internal Electronic Failure GO to Pinpoint Test G 
WACM U3003:16 Battery Voltage: Circuit Voltage Below Threshold GO to Pinpoint Test C 
WACM U3003:17 Battery Voltage: Circuit Voltage Above Threshold GO to Pinpoint Test C 
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.