Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
2020 Ford Escape Titanium Plug-In HybridFACTORY OEM SERVICE PROCEDURE
Pinpoint Test He: Exhaust Gas RECIRCULATION (EGR) Systems: Introduction
Normal OperationÂ
Refer to
DTC Fault Trigger ConditionsÂ
| DTC | Description | Fault Trigger Condition |
| PCMÂ P0401:00 |
EGR 'A' Flow Insufficient Detected: No Sub Type Information | Sets when PCMÂ detects the signal from the differential pressure feedback EGRÂ sensor indicates that EGRÂ flow is less than the desired minimum. The EGRÂ system is monitored during steady state driving conditions while the EGRÂ is commanded on. |
| PCMÂ P0402:00 |
EGR 'A' Flow Excessive Detected : No Sub Type Information | Sets when PCMÂ
detects the signal at idle is greater than at KOEOÂ
by a calibrated amount. The EGRÂ
system is monitored for undesired EGRÂ
flow during idle. The EGRÂ
monitor looks at the differential pressure feedback EGRÂ
signal at idle and compares it to the stored signal measured during KOEO. A DPFEGR PIDÂ reading that is greater at idle than during KOEOÂ by 0.5 volt or a rough engine idle may indicate a concern. On some applications P0402 can set while driving. View the freeze frame data to determine the operating conditions when the DTCÂ was set. |
| PCMÂ P044C:00 |
EGR Sensor 'C' Circuit Low : No Sub Type Information |
Sets when PCMÂ detects the average voltage to the PCMÂ drops to a voltage less than the minimum calibrated value. The EGRÂ monitor checks the differential pressure feedback EGR sensor signal to the PCMÂ for low voltage. |
| PCMÂ P044D:00 |
EGR Sensor 'C' Circuit High : No Sub Type Information |
Sets when PCMÂ detects the average voltage to the PCMÂ exceeds the maximum calibrated value. The EGRÂ monitor checks the differential pressure feedback EGRÂ sensor signal to the PCMÂ for high voltage. |
| PCMÂ P139A:00 |
EGR Sensor 'C' Hoses Reversed: No Sub Type Information | Sets when PCMÂ
detects the average the differential pressure indicated by the sensor exceeds a maximum threshold or falls below a minimum threshold. At idle, the EGRÂ
monitor commands the EGR valve closed and checks the differential pressure across the EGR tube orifice which should be zero to indicate the hoses are connected and not restricted. Look for signs of water or icing in the hose. Verify the hose connection and routing. Check the differential pressure feedback EGRÂ sensor for correct mounting and function. |
| PCMÂ P139B:00 |
EGR Sensor 'C' Upstream Hose Off or Plugged: No Sub Type Information |
Sets when PCMÂ
detects the differential pressure indicated by the sensor exceeds a maximum threshold or falls below a minimum threshold. At idle, the EGRÂ
monitor commands the EGR valve closed and checks the differential pressure across the EGR tube orifice which should be zero to indicate the hoses are connected and not restricted. Look for signs of water or icing in the hose. Verify the hose connection and routing. Check the differential pressure feedback EGRÂ sensor for correct mounting and function. |
| PCMÂ P139C:00 |
EGR Sensor 'C' Downstream Hose Off or Plugged: No Sub Type Information |
Sets when PCMÂ
detects the differential pressure indicated by the sensor exceeds a maximum threshold or falls below a minimum threshold. At idle, the EGRÂ
monitor commands the EGR valve closed and checks the differential pressure across the EGR tube orifice which should be zero to indicate the hoses are connected and not restricted. Look for signs of water or icing in the hose. Verify the hose connection and routing. Check the differential pressure feedback EGRÂ sensor for correct mounting and function. |
| PCMÂ P1408:00 |
EGR Flow Out Of Self Test Range: No Sub Type Information |
Sets when PCMÂ detects the measured EGR flows falls above or below the required calibration. This test is carried out during the key ON, KOERÂ on demand self-test only. The EGRÂ system is commanded on at a fixed engine speed. |
| PCMÂ P2457:00 |
EGR Cooler 'A' Efficiency Below Threshold: No Sub Type Information |
Sets when PCMÂ detects the difference between the expected temperature of the exhaust gas and the actual EGRTÂ bank 1, sensor 2 value is greater than a calibrated amount. |
Possible CausesÂ
- Cooling System Concern
- Differential Pressure Feedback EGRÂ Circuitry Concern
- Differential Pressure Feedback EGRÂ Sensor Hose
- EGRÂ Cooler
- EGRÂ Valve
- Differential Pressure Feedback EGRÂ Sensor
- Orifice tube assembly
- PCMÂ
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.