2020 Ford Edge ST-Line, FWDFACTORY OEM SERVICE PROCEDURE

Front Controls Interface Module (FCIM)

NOTE: Some PCM Diagnostic Trouble Codes (DTCs) may inhibit A/C operation. If any PCM Diagnostic Trouble Codes (DTCs) are retrieved, diagnose those first. Refer to PCM DTC Chart .

Diagnostics in this article assume a certain skill level and knowledge of Ford-specific diagnostic practices. REFER to: Diagnostic Methods .

Network Diagnostic Trouble Codes (DTCs) (U-codes) are often a result of intermittent concerns such as damaged wiring or low battery voltage occurrences. Additionally, vehicle repair procedures, such as module reprogramming, often set network Diagnostic Trouble Codes (DTCs). Replacing a module to resolve a network DTC is unlikely to resolve the concern. To prevent repeat network DTC concerns, inspect all network wiring, especially connectors. Test the vehicle battery. REFER to: Battery .

DTC Description Action
B105A:12 Cabin Temperature Sensor Fan: Circuit Short To Battery GO to Pinpoint Test N
B105A:14 Cabin Temperature Sensor Fan: Circuit Short To Ground or Open GO to Pinpoint Test N
B1081:07 Left Temperature Damper Motor: Mechanical Failure GO to Pinpoint Test I
B1081:11 Left Temperature Damper Motor: Circuit Short To Ground GO to Pinpoint Test I
B1081:12 Left Temperature Damper Motor: Circuit Short To Battery GO to Pinpoint Test I
B1081:13 Left Temperature Damper Motor: Circuit Open GO to Pinpoint Test I
B1082:07 Right Temperature Damper Motor: Mechanical Failure GO to Pinpoint Test J
B1082:11 Right Temperature Damper Motor: Circuit Short To Ground GO to Pinpoint Test J
B1082:12 Right Temperature Damper Motor: Circuit Short To Battery GO to Pinpoint Test J
B1082:13 Right Temperature Damper Motor: Circuit Open GO to Pinpoint Test J
B1083:07 Recirculation Damper Motor: Mechanical Failure GO to Pinpoint Test D
B1083:11 Recirculation Damper Motor: Circuit Short To Ground GO to Pinpoint Test D
B1083:12 Recirculation Damper Motor: Circuit Short To Battery GO to Pinpoint Test D
B1083:13 Recirculation Damper Motor: Circuit Open GO to Pinpoint Test D
B1086:07 Air Distribution Damper Motor: Mechanical Failure GO to Pinpoint Test E
B1086:11 Air Distribution Damper Motor: Circuit Short To Ground GO to Pinpoint Test E
B1086:12 Air Distribution Damper Motor: Circuit Short To Battery GO to Pinpoint Test E
B1086:13 Air Distribution Damper Motor: Circuit Open GO to Pinpoint Test E
B10AF:11 Blower Fan Relay: Circuit Short To Ground GO to Pinpoint Test L
B10AF:15 Blower Fan Relay: Circuit Short To Battery or Open For an inoperative blower motor, GO to Pinpoint Test K
For all other blower motor symptoms, GO to Pinpoint Test L
B10B3:11 Right Panel Air Discharge Temperature: Circuit Short To Ground GO to Pinpoint Test M
B10B3:15 Right Panel Air Discharge Temperature: Circuit Short To Battery or Open GO to Pinpoint Test M
B10B4:11 Right Floor Air Discharge Temperature: Circuit Short To Ground GO to Pinpoint Test M
B10B4:15 Right Floor Air Discharge Temperature: Circuit Short To Battery or Open GO to Pinpoint Test M
B10B5:11 Left Panel Air Discharge Temperature: Circuit Short To Ground GO to Pinpoint Test M
B10B5:15 Left Panel Air Discharge Temperature: Circuit Short To Battery or Open GO to Pinpoint Test M
B10B6:11 Left Floor Air Discharge Temperature: Circuit Short To Ground GO to Pinpoint Test M
B10B6:15 Left Floor Air Discharge Temperature: Circuit Short To Ground GO to Pinpoint Test M
B10B9:12 Blower Control: Circuit Short To Battery GO to Pinpoint Test K
B10B9:14 Blower Control: Circuit Short To Ground or Open For an inoperative blower motor, GO to Pinpoint Test K
For all other blower motor symptoms, GO to Pinpoint Test L
B11E5:11 Left HVAC Damper Position Sensor: Circuit Short To Ground GO to Pinpoint Test I
B11E5:15 Left HVAC Damper Position Sensor: Circuit Short To Battery or Open GO to Pinpoint Test I
B11E6:11 Right HVAC Damper Position Sensor: Circuit Short To Ground GO to Pinpoint Test J
B11E6:15 Right HVAC Damper Position Sensor: Circuit Short To Battery or Open GO to Pinpoint Test J
B11E7:11 Air Distribution Damper Position Sensor: Circuit Short To Ground GO to Pinpoint Test E
B11E7:15 Air Distribution Damper Position Sensor: Circuit Short To Battery or Open GO to Pinpoint Test E
B11F0:11 Air Intake Damper Position Sensor: Circuit Short To Ground GO to Pinpoint Test D
B11F0:15 Air Intake Damper Position Sensor: Circuit Short To Battery or Open GO to Pinpoint Test D
B1A61:11 Cabin Temperature Sensor: Circuit Short To Ground GO to Pinpoint Test N
B1A61:15 Cabin Temperature Sensor: Circuit Short To Battery or Open GO to Pinpoint Test N
B1A63:11 Right Solar Sensor: Circuit Short To Ground GO to Pinpoint Test O
B1A63:15 Right Solar Sensor: Circuit Short To Battery or Open GO to Pinpoint Test O
B1A64:11 Left Solar Sensor: Circuit Short To Ground GO to Pinpoint Test O
B1A64:15 Left Solar Sensor: Circuit Short To Battery or Open GO to Pinpoint Test O
B1A69:11 Humidity Sensor: Circuit Short To Ground GO to Pinpoint Test N
B1A69:15 Humidity Sensor: Circuit Short To Battery or Open GO to Pinpoint Test N
B1B71:11 Evaporator Temperature Sensor: Circuit Short To Ground GO to Pinpoint Test P
B1B71:15 Evaporator Temperature Sensor: Circuit Short To Battery or Open GO to Pinpoint Test P
C1B14:11 Sensor Supply Voltage A: Circuit Short To Ground GO to Pinpoint Test Q
C1B14:12 Sensor Supply Voltage A: Circuit Short To Battery GO to Pinpoint Test Q
All Other FCIM Diagnostic Trouble Codes (DTCs) not listed in this chart -- Refer to the appropriate Information and Entertainment Systems article for the procedure.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.