Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
Auxiliary Coolant System Pumps
Some engines will include an auxiliary coolant system pump that is PCM controlled. This is a second cooling pump in the main cooling loop. It is a low power electrically controlled pump which is used to provide engine coolant flow under conditions when the engine is not running and the main mechanical cooling pump is inactive. These auxiliary pumps can be used for two primary purposes: 1) to provide coolant flow through the cabin heat exchanger (heater core) which generates heat for the vehicle cabin (stop/start equipped vehicles), and 2) to provide coolant flow to engine components for the purposes of component protection after the engine is shut-off. On turbo equipped vehicles, engine coolant is used to cool the turbo system bearings resulting in a thermal transfer of heat into the coolant. After-run coolant flow may be required to prevent localized coolant boiling that can damage some cooling system components (particularly the degas bottle).
Coolant Pump "A"
"A" is defined as "High Temp Loop Aux Pump - Cabin Heating" and refers to the auxiliary pump in the primary coolant loop which supplies the heater core for cabin heating. It is used on stop/start applications and HEV/PHEV applications.
The auxiliary cooling pump diagnostics include circuit checks for Open (P2600), short-to-power (P2603), short-to-ground (P2602), and a functional performance check (P2601).
| DTCs | P2600 - Coolant Pump "A" Control Circuit/Open P2601 - Coolant Pump "A" Control Performance/Stuck Off P2602 - Coolant Pump "A" Control Circuit Low P2603 - Coolant Pump "A" Control Circuit High "A" is defined as "High Temp Loop Aux Pump - Cabin Heating" |
| Monitor Execution | Continuous |
| Monitor Sequence | None |
| Sensors OK | Not Applicable |
| Monitoring Duration | 5 seconds |
| Entry Condition | Minimum | Maximum |
| Battery Voltage | 11.0 Volts |
| P2602/P2603 - Smart driver reports output circuit fault. |
Coolant Pump "B"
"B" is defined as High Temp Loop Aux Pump - Component Cooling #1" and refers to the auxiliary pump in the secondary coolant loop which supplies the CAC and turbo.
The auxiliary cooling pump diagnostics include circuit checks for Open (P261A), short-to-power (P261D), short-to-ground (P261C), and a functional performance check (P26B1).
| DTCs | P261A - Coolant Pump "B" Control Circuit/Open P261B1 - Coolant Pump "B" Control Performance/Stuck Off P261C - Coolant Pump "B" Control Circuit Low P261D - Coolant Pump "B" Control Circuit High "B" is defined as High Temp Loop Aux Pump - Component Cooling #1" |
| Monitor Execution | Continuous |
| Monitor Sequence | None |
| Sensors OK | Not Applicable |
| Monitoring Duration | 5 seconds |
| Entry Condition | Minimum | Maximum |
| Battery Voltage | 11.0 Volts |
| P261C/P261D - Smart driver reports output circuit fault. |
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.
Rather have a pro handle this?
A certified mobile mechanic comes to your home or office. They bring the tools, you stay comfortable. No tow truck, no waiting room, no surprises.
No obligation. See pricing before you book.