DTC P0344 - Camshaft Position Sensor A Circuit Intermittent (Bank 1 Or Single Sensor)

P0344 - CAMSHAFT POSITION SENSOR A CIRCUIT INTERMITTENT (BANK 1 OR SINGLE SENSOR)

Description:  This DTC sets when the PCM detects an intermittent signal from the camshaft position 11 (CMP11) sensor.
Possible Causes: 
  • VBPWR circuit intermittent open
  • CMP11 circuit intermittent open
  • CMP11 circuit intermittent short to ground
  • CMP11 circuit intermittent short to voltage
  • SIGRTN circuit intermittent open
  • SIGRTN circuit intermittent short to voltage
  • Intermittent short circuit
  • Damaged CMP11 sensor shielding
  • Damaged CMP11 sensor
Diagnostic Aids:  Harness routing, harness alterations, incorrect shielding, or electrical interference from other systems may have an intermittent impact on the CMP11 signal.
Application  Key On Engine Off  Key On Engine Running  Continuous Memory 
All GO to PINPOINT TEST DR .
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.

Rather have a pro handle this?

A certified mobile mechanic comes to your home or office. They bring the tools, you stay comfortable. No tow truck, no waiting room, no surprises.

Comes to youSame-day available12-month warranty
Get a Free Quote

No obligation. See pricing before you book.